Lynx Conductor / Re: Strange conductor behavior
« on: November 20, 2012, 06:56:39 pm »
You are not allowed to view links. Register or Login
Sounds like to me a cold solder joint that works sometimes but not all of the time. Check for solder bridges and reflow the solder joints.

Rick R.


Well, I did that and it did the reboot thing a few times and then came on.  It's currently working now, so hopefully I can get it to stay that way :)

Thanks for your help.  I'll report back if I run into the problem again

-Brandon

2
Lynx Conductor / Re: Strange conductor behavior
« on: November 20, 2012, 05:56:16 pm »
You are not allowed to view links. Register or Login
This probably isn't the issue since you say it works fine as an Etd, but have you tried with it directly connected to your PC?

I assume you mean connecting the ethernet from the conductor directly to the ethernet on my computer, bypassing the switch? Yes I have done that, with the same result.

3
Lynx Conductor / Strange conductor behavior
« on: November 20, 2012, 05:40:21 pm »
I have had some strange behavior with my conductor.  Most of the time it doesn't work, but then it will suddenly start working.  Last night I messed with it for over an hour - resetting the switch and conductor, reformatting the card rebuilding it, etc.
Then all of the sudden after a reboot, it started working.  I let it run overnight, and it was still going strong in the morning.

I then powercycled it, and it stopped working.  I have been messing with it for over an hour now and still no luck.  Continue reading for more details:

When I say "not working", the Green light on the ethernet port comes on for a couple seconds, then turns off. it does this forever.

I have had wireshark running through the entire process, and every time I plug in the power to the conductor, i get a single packet.  (just when i plug in the power, not every time the green light comes on like others have seen).  The data I get in wireshark is this:

0000  ff ff ff ff ff ff 00 04  a3 b2 44 45 08 00 45 00   ........ ..DE..E.
0010  00 24 00 01 00 00 64 11  94 85 c0 a8 01 9b ff ff   .$....d. ........
0020  ff ff 0b 2c 15 c0 00 10  71 f4 55 55 55 55 00 00   ...,.... q.UUUU..
0030  00 00 00 00 00 00 00 00  00 00 00 00               ........ ....   

Now, when I unplug the CF card, and powercycle, I get two packets.  The one above, and then this one:

0000  ff ff ff ff ff ff 00 04  a3 b2 44 45 08 00 45 00   ........ ..DE..E.
0010  00 3d 00 02 00 00 64 11  94 6b c0 a8 01 9b ff ff   .=....d. .k......
0020  ff ff 0b 2c 15 c0 00 29  c9 07 55 aa 98 55 65 65   ...,...) ..U..Uee
0030  00 00 00 00 00 00 00 00  00 00 00 00 00 00 00 00   ........ ........
0040  00 00 00 00 00 00 00 00  00 00 00                  ........ ...     

I assume this is the card error packet that gets sent out, and the lynx control panel does in fact show the card error message.  I get these two packets only one time, even though the green light is going on and off.

As far as the CF card goes, I have been formatting it as fat32, and setting the password, creating the shows, and creating the schedule. filenames are 8.3, and as I have said before, I have been able to get it working at one point, so I am pretty sure my CF card is built up correctly.

I have reflashed the firmware more than once.  I've even taken the firmware back to just the ETD firmware, and that worked for me.  So i am guessing it's the conductor side of things.

Does anyone have any ideas or suggestions as to what I might try?

4
Lynx Smart String / Re: DSC Programming Issue
« on: November 20, 2012, 01:18:55 am »
You are not allowed to view links. Register or Login
i use flex strips that turns out the colors are wrong from what printed on the strip.

Yeah, it looks like mine are a little messed up as well. In the end, I ended up fixing the mismatched colors, and programming the DSC's start channel to CHANNEL+1, and it looks like it is working.

Sure do wonder why its off by one though. 

-Brandon

5
Lynx Smart String / Re: DSC Programming Issue
« on: November 19, 2012, 09:51:08 pm »
You are not allowed to view links. Register or Login
Double check your wiring from the DSC to the strings

I double-checked once again just to be sure, and everything is right.  Even if they are wrong, that wouldn't explain why it assigned a color to channel 512, when my starting channel is 513.

-Brandon

6
Lynx Smart String / DSC Programming Issue
« on: November 19, 2012, 09:43:25 pm »
I am having a strange issue while programming a DSC.

I set the start channel to 513, node count 1.
When I go into vixen to test the channels, the output is as follows:
512 - Blue
513 - Red
514 - Green

So it looks like it sucessfully programmed the start channel to red, and the next is green, but for some reason, the blue went backwards.

I have tried changing the Mode, and Smart String Device Type, to see if there's any difference, but I get the same result.

Any suggestions?

7
Sale/Trade / WTB - Active Hub
« on: November 07, 2012, 06:45:22 pm »
Looking to buy an active hub.  I didn't realize the conductor doesn't have Dmx firmware available, and all my devices are DMX!

If anyone has an active hub to spare, i'm definitely interested in buying!
PM me

Brandon

8
Lynx Conductor / Re: firmware
« on: November 06, 2012, 12:59:30 pm »
ergh!

This is a killer for my show. I don't have an active hub, and all my hardware is DMX. 

Any chance of a beta release we can try?

9
Finished COOPS / Re: Etherdongle (EtD) COOP *** Closed for Orders ****
« on: October 17, 2012, 09:28:12 pm »
You are not allowed to view links. Register or Login
none of the EtDs come programmed.  you need to assemble enough of the board to be able to do the programming.

Doh!  That's what I thought. I had assumed the pickit2 would work. But now I see I need a pickit3.

10
Finished COOPS / Re: Etherdongle (EtD) COOP *** Closed for Orders ****
« on: October 17, 2012, 09:09:55 pm »
Got my etherdongle in the mail today, and got it all soldered!

Quick question though: is the PIC already programmed, or do I have to program it myself?


11
Finished COOPS / Re: Conductor, Slave and Trigger COOP
« on: September 18, 2012, 04:47:52 pm »
1x kit #1
1x kit #3

Thanks!

12
Finished COOPS / Re: Etherdongle (EtD) COOP
« on: August 25, 2012, 11:54:36 pm »
one for me please!

:)

13
Sale/Trade / WTB: etherdongle, or 16 port active hub
« on: August 04, 2012, 04:20:05 pm »
If anyone has any spares, I would be very interested in buying it off you.
I'll take one built, or a kit, or even just the PCB if I have to.
PM if interested.

-brandon

14
The Porch / coop rumors?
« on: August 04, 2012, 02:41:08 pm »
I really need an ether dongle, and a conductor would be awesome too!

15
Lynx EtherDongle / Re: How many people need EtherDongles?
« on: July 17, 2012, 06:02:09 pm »
I will be buying one if there is another coop

Pages: [1] 2 3